Doppler Animal Blood Pressure Monitor Designed for Pets and Animals

Customization: Available
Classification: Imaging Diagnostic Equipment
Certification: CE, FDA, ISO13485

Product Description

Basic Info

Model NO. YJ-B200
Group Infants and Young Children
Name Doppler Animal Blood Pressure Monitor
Probe 9 MHz
Battery DC 7.4V 2600mAh Lithium Battery
Earphone Dual Rack 270Ω 3.5mm Plug
Warranty 1 Years
Speaker 4Ω 1W
Dimensions (Host) 160mm(L) *90mm(W)*40mm(H)
Production Capacity 3000 Pieces/Month

Product Description

Doppler animal blood pressure monitor designed for pets and animals

Product View 1
Product View 2
Product View 3
Product View 4
Product View 5
Product View 6
Clinical Use 1
Clinical Use 2
Clinical Use 3

Technical Specification

Probe 9 MHz
Battery DC 7.4V 2600mAh lithium battery
Speaker 4Ω 1W
Earphone dual rack 270Ω 3.5mm Plug
Host 160mm(L) *90mm(W)*40mm(H)
Package 37mm(L)*31mm(W)*14mm(H)

Clinical Application Skills

1
It is advised not to fasten the probe when in examination in the section of outpatient. Because the sound of artery will disappear when pet moves. It is better to press the probe with one's finger.
2
There is needing to apply a little more pressure to make the probe contact pets skin as much as possible.
3
It is advised to listen to the sound of pulse with earphone because the sound can be heard clearer and pets can be protected from being scared by the sound.
4
If using speaker, please appropriate volume. If too loud, it is not good to ear and some sound will be missed.
5
Keeping pet's leg straight. If not, blood flow will be influenced and the examination result will not be so accurate.
6
It is better to do the measurement for 6 to 7 times so that pets become calm. First few numerical values will be higher; following values will be lower and stable.

Important Notes

Probe Maintenance

Please turn off the power immediately after usage. The probe should be protected carefully. Do not crash or collide the expensive probe with other things to avoid damaging the internal chip.

Couplant Usage

It is not allowed to use ECG viscose, baby oil, or other oils. Use only dedicated couplant, as other oils will corrode and damage the probe.

Battery Indicator

When the power light becomes dark and the speaker stops working, it is necessary to change the battery.

Shipping and Payment

Shipping and Payment

FAQ

What is the frequency of the probe?
The Doppler Animal Blood Pressure Monitor uses a high-sensitivity 9 MHz probe.
What type of battery does the device require?
The device is powered by a DC 7.4V 2600mAh lithium battery.
Can I use standard ECG gel or oils as a couplant?
No, it is strictly advised to use only dedicated ultrasound couplant. Other oils or ECG viscose can corrode and damage the probe chip.
Why is it recommended to use earphones during examination?
Using earphones allows the operator to hear the pulse more clearly and prevents the pet from being startled by the loud speaker sounds.
How many measurements should be taken for a stable result?
It is recommended to perform the measurement 6 to 7 times. The final similar and stable values are considered the accurate usual values once the pet has calmed down.
What should I do if the sound of the artery disappears during examination?
If the pet moves and the sound disappears, simply reposition the probe or press it slightly with your finger to regain the signal.