My-D054A Hospital Equipment 0.5t MRI Scanner for Sale

Customization: Available
Classification: Imaging Diagnostic Equipment
Type: Medical MRI Equipments

Product Description

🌐 Basic Information
Model NO. MY-D054A
Transport Package Carton
Origin China
Production Capacity 100,000
📋 Product Description

MY-D054A Dual Pillar Magnet Design Hospital 0.5T Medical MRI Equipment

1, 300mA Medical X-ray machine (MA300A), X-ray equipment for hospitals. Detailed product specifications and configurations are listed below.

⚙️ Use & Configuration
🔹
General Radiography: Filter-ray-filter radiograph applications.
🔹
Unit Configuration: Control unit, HT generator unit, HT cable, X-ray tube unit, Radiographic table with X-ray source column, and Collimator.
🔹
Power & Tube: HT generator unit with 300mA tube currency.
⚡ Main Characteristics
Single-table/single-tube design for streamlined operations.
Rotary anode X-ray tube unit with tangential annular tube head.
Single-phase full wave rectification high-voltage generator.
Step-less control electric mechanism for power voltage (v) and radiograph kilovolt (KV).
Filament stabilizer for X-ray tube unit and space charge compel mentor.
Advanced radiograph volume control for KV, mA, and S with grading and interlock protection.
Digital circuit timer following R10 priority coefficient for high-accuracy time control.
HT primary zero controlled circuit using heavy power silicon-controlled rectifier.
Radiographic table features length and breadth mobility for versatile positioning.
Integrated radiographic table, column, and vibrating grid design without requiring ceiling or floor rails.
❓ Frequently Asked Questions
Q1: What is the main application of the MY-D054A equipment? A: It is primarily used for general radiography and filter-ray-filter radiograph procedures in hospital environments.
Q2: What are the power specifications for this medical system? A: The unit features a 300mA tube currency and a single-phase full wave rectification high-voltage generator.
Q3: How is the exposure time controlled? A: It adopts a digital circuit timer graded according to the R10 priority coefficient for more accurate time control.
Q4: Does the radiographic table require special floor or ceiling rails? A: No, the radiographic table, column, and vibrating grid are integrated into a whole unit without the need for ceiling or floor rails.
Q5: What kind of X-ray tube unit is utilized in this model? A: It utilizes a rotary anode X-ray tube unit with a tangential annular tube head.
Q6: Is there any protection mechanism for KV and mA settings? A: Yes, the system includes grading and interlock protection for radiograph volume KV, mA, and S settings.