Portable Veterinary Infusion Pump for Clinics and Hospitals

Customization: Available
Classification: Infusion Pump
Type: Infusion Pump

Product Description

📋 Basic Information
Model NO.
SP750VET
Product Type
Volumetric Infusion Pump
Infusion Rate
1~699 Ml/H
Total Volume
1~9999 Ml
Accuracy
±5%
Waterproof Degree
Ipx2
Safety Classification
Class II
Power Supply
100-240 V~, 50/60 Hz
Weight
1.9kg
Dimension
143.6mm(L)×151.8mm(W)×195.3mm(H)
HS Code
9018390000
Origin
China
Portable Injection Infusion Pump for Medical Use
🌟 Product Features
Compatible with multiple infusion set brands; new brands can be calibrated for accuracy.
2.8-inch TFT LCD screen displaying real-time infusion parameters and remaining time.
Anti-spill mechanism prevents fluid leakage when the pump door is opened.
High-precision ultrasonic sensor with 0.02 ml air bubble detection accuracy.
Comprehensive audible and visual alarm system for blockages, air bubbles, and motor anomalies.
Automatically switches to KVO (Keep Vein Open) speed upon infusion completion.
Dual power supply: External AC and built-in high-capacity lithium battery.
⚙️ Technical Specifications
Infusion Rate: 1~699mL/h (1mL/h increments)
Total Volume: 1~9999mL (1mL increments)
Accuracy: ±5% (using calibrated infusion set)
Safety Class: Class I BF, Ingress Protection IPX2
KVO Rate: 1mL/h
Battery: Rechargeable lithium-ion battery, 7.4V/5000mAh
Special Measures: Automatic infusion clamp, pressure sensor for obstruction detection, password-protected parameters.
📦 Physical Characteristics & Accessories
Dimension143.6 mm (L) × 151.8 mm (W) × 195.3 mm (H)
WeightApprox. 1.9 kg
AccessoriesUser manual ×1, Power cord ×1, Veterinary hook ×1
Frequently Asked Questions (FAQ)
Q: Can I use different brands of infusion sets with this pump? A: Yes, the SP750VET is compatible with multiple infusion set brands. New brands can be calibrated within the system to ensure high infusion accuracy.
Q: What happens if there is an air bubble in the line? A: The pump features a high-precision ultrasonic bubble detector (accuracy of 0.02 ml) that will trigger an audible and visual alarm to prevent air from entering the body.
Q: Does the pump keep working if there is a power outage? A: Yes, it has a dual power supply system. If external AC power is lost, it automatically switches to the built-in high-capacity 7.4V/5000mAh lithium battery.
Q: What is the KVO rate and when does it start? A: The KVO (Keep Vein Open) rate is 1mL/h. It starts automatically once the preset infusion volume has been completed to prevent blood backflow.
Q: Are the settings protected from accidental changes? A: Yes, infusion parameters are protected during operation, and system configuration settings are password-protected to prevent unauthorized modifications.